APPENDIX B.  SUMMARY OF CONSTRUCTION DATA (continued)

Michigan (26)
113114115116117118119120121122123124159
Required Thickness
AC Surface
102
178
178
102
178
102
178
102
102
102
178
178
 
ATB
0
0
203
305
102
203
0
0
0
102
203
305
 
PATB
0
0
0
0
0
0
102
102
102
102
102
102
 
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
 
L05B Thickness
AC Surface
112
165
 
104
163
84
163
94
94
97
178
152
 
ATB
0
0
244
305
132
211
0
0
0
107
203
305
 
PATB
0
0
0
0
0
0
102
102
102
102
102
102
 
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
 
SPS Construction Thickeness
AC Surface
             
ATB
             
PATB
             
DGAB
             
Rod & Level
AC Surface
             
ATB
             
PATB
             
DGAB
             
Rod & Level Std Dev
AC Surface
             
ATB
             
PATB
             
DGAB
             
Rod & Level Min
AC Surface
             
ATB
             
PATB
             
DGAB
             
Rod & Level Max
AC Surface
             
ATB
             
PATB
             
DGAB
             
DGAB Material Requirements
< 50% Passing #4 Sieve
53
34
           
< 10 % Passing #200
11
8
           
LL < 25
             
PI < 4
NP
NP
           
Max Lift Thickness < 6
             
ATB Material Requirements
Hveem
Swell < 0.7 mm
             
Stability > 35
             
Marshall 50-blow
Flow 2 - 5 mm
             
Stability 4.4 kN
             
Marshall 75-blow
Flow 3 - 7.6 mm
             
Stability 10 kN
             
First lift thickness < 6 inches
             
Sub lift thickness < 4
             
PATB Material Requirements
             
< 2% Passing #200
             
2 - 2.5% Ashpalt Content
             
Roller type (Steel Wheel)
       
Drainage Locations
             
Drainage Type
             
HMAC Binder Material Requirements
Marshall
75 blows
             
Min Stability
             
Flow 2 mm - 4 mm
             

Montanta (30)
113114115116117118119120121122123124
Required Thickness
AC Surface
102
178
178
102
178
102
178
102
102
102
178
178
ATB
0
0
203
305
102
203
0
0
0
102
203
305
PATB
0
0
0
0
0
0
102
102
102
102
102
102
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
L05B Thickness
AC Surface
            
ATB
            
PATB
            
DGAB
            
SPS Construction Thickeness
AC Surface
            
ATB
            
PATB
            
DGAB
            
Rod & Level
AC Surface
109
 
189
113
183
118
183
108
114
116
191
183
ATB
0
 
232
317
110
223
0
0
0
102
214
326
PATB
0
 
0
0
0
0
118
116
109
110
99
109
DGAB
210
 
0
0
120
108
112
206
312
0
0
0
Rod & Level Std Dev
AC Surface
11
 
7
5
7
6
10
6
8
16
6
9
ATB
  
9
7
7
10
   
7
9
5
PATB
      
6
7
8
10
10
8
DGAB
24
   
18
22
17
17
11
   
Rod & Level Min
AC Surface
81
 
168
104
165
104
157
91
86
18
180
170
ATB
0
 
216
305
89
203
0
0
0
91
201
318
PATB
0
 
0
0
0
0
107
102
91
91
76
97
DGAB
102
 
0
0
91
74
76
170
287
0
0
0
Rod & Level Max
AC Surface
142
 
201
124
203
137
201
124
127
135
203
198
ATB
0
 
249
330
122
244
0
0
0
122
231
330
PATB
0
 
0
0
0
0
127
127
122
127
119
122
DGAB
244
 
0
0
173
157
142
244
330
0
0
0
DGAB Material Requirements
< 50% Passing #4 Sieve
            
< 10 % Passing #200
            
LL < 25
            
PI < 4
            
Max Lift Thickness < 6
    
5
5
5
8
8
   
ATB Material Requirements
Hveem
Swell < 0.7 mm
            
Stability > 35
            
Marshall 50-blow
Flow 2 - 5 mm
            
Stability 4.4 kN
            
Marshall 75-blow
Flow 3 - 7.6 mm
            
Stability 10 kN
            
First lift thickness < 6 inches
  
2
2
2
2
   
2
2
2
Sub lift thickness < 4
  
3
2
2
2
   
2
2
2
PATB Material Requirements
< 2% Passing #200
            
2 - 2.5% Ashpalt Content
            
Roller type (Steel Wheel)
      DOUBLE-DRUM VIBR.
Drainage Locations
      
1
1
    
Drainage Type
      
6
6
    
HMAC Binder Material Requirements
Marshall
75 blows
50
50
50
50
50
50
50
50
50
50
50
50
Min Stability
10
10
10
10
10
10
10
10
10
10
10
10
Flow 2 mm - 4 mm
3
3
3
3
3
3
3
3
3
3
3
3

Nebraska (31)
113114115116117118119120121122123124
Required Thickness
AC Surface
102
178
178
102
178
102
178
102
102
102
178
178
ATB
0
0
203
305
102
203
0
0
0
102
203
305
PATB
0
0
0
0
0
0
102
102
102
102
102
102
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
L05B Thickness
AC Surface
 
170
 
112
201
109
201
119
 
97
191
190.5
ATB
0
0
323
323
97
213
0
0
0
112
206
312.4
PATB
0
0
0
0
0
0
102
102
102
102
102
101.6
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
SPS Construction Thickeness
AC Surface
       
102
102
   
ATB
       
203
305
   
PATB
       
102
102
   
DGAB
       
0
0
   
Rod & Level
AC Surface
            
ATB
            
PATB
            
DGAB
            
Rod & Level Std Dev
AC Surface
            
ATB
            
PATB
            
DGAB
            
Rod & Level Min
AC Surface
            
ATB
            
PATB
            
DGAB
            
Rod & Level Max
AC Surface
            
ATB
            
PATB
            
DGAB
            
DGAB Material Requirements
< 50% Passing #4 Sieve
            
< 10 % Passing #200
            
LL < 25
            
PI < 4
            
Max Lift Thickness < 6
       
6
    
ATB Material Requirements
Hveem
Swell < 0.7 mm
            
Stability > 35
            
Marshall 50-blow
Flow 2 - 5 mm
            
Stability 4.4 kN
            
Marshall 75-blow
Flow 3 - 7.6 mm
            
Stability 10 kN
            
First lift thickness < 6 inches
            
Sub lift thickness < 4
            
PATB Material Requirements
< 2% Passing #200
        
7
   
2 - 2.5% Ashpalt Content
        
5
  
2.5
Roller type (Steel Wheel)
      
DOUBLE-DRUM VIBR.
Drainage Locations
            
Drainage Type
            
HMAC Binder Material Requirements
Marshall
75 blows
            
Min Stability
            
Flow 2 mm - 4 mm
            

 

Nevada (32)
101102103104105106107108109110111112
Required Thickness
AC Surface
178
102
102
178
102
178
102
178
178
178
102
102
ATB
0
0
203
305
102
203
0
0
0
102
203
305
PATB
0
0
0
0
0
0
102
102
102
102
102
102
DGAB
203
305
0
0
102
102
102
203
305
0
0
0
L05B Thickness
AC Surface
183
112
104
185
107
183
112
178
178
168
104
114
ATB
0
0
224
305
122
224
0
0
0
107
213
315
PATB
0
0
0
0
0
0
104
114
102
112
112
107
DGAB
216
297
0
0
91
94
97
196
307
0
0
0
SPS Construction Thickeness
AC Surface
180
112
104
185
107
183
112
178
178
168
104
114
ATB
0
0
224
315
122
224
0
0
0
107
213
315
PATB
0
0
0
0
0
0
104
114
102
112
112